Description
SICK C40S-1203CA010 1018647
-
- Various options for blanking objects: fixed, floating, or teach-in
- Reduced resolution
- 7-segment display
- Beam coding for correct system allocation
- Cascadable up to three systems
- PSDI mode with the UE402 switching amplifier
- Configuration and diagnostics via PC
- External device monitoring (EDM) and restart interlock (RES)
Your benefits
- Blanking functions enable reliable and safe object detection and increase the productivity in the process
- 7-segment display saves time during alignment and diagnostics
- Beam coding protects the systems against opticalinterference by ensuring a high level of availability
- Clone plug enables easy and rapid commissioning, saving time and costs
- Ability to cascade up to three systems optimizes the safety application and reduces wiring costs
- Precise, convenient configuration and diagnostics reduce downtime
| Technical Data-Sender | |
| Protective field height: | 1,200 mm |
| Resolution: | 30 mm |
| Housing length: | 1,329 mm |
| Housing cross-section: | 48 mm x 40 mm |
| Type: | Type 4 (IEC 61496) |
| Safety integrity level: | SIL3 (IEC 61508), SILCL3 (IEC 62061) |
| Category: | category 4 (EN ISO 13849) |
| Performance level: | PL e (EN ISO 13849) |
| PFHd: | 1.5 * 1E-08 |
| TM (Mission Time): | 20 a |
| Enclosure rating: | IP 65 |
| Protection class: | III |
| Ambient operating temperature from … to: | 0 °C … 55 °C |
| Vibration resistance (checked to): | 5 g (IEC 60068-2-6) |
| Oscillation frequency from … to: | 10 Hz … 55 Hz |
| Shock resistance: | 10 g, 16 ms (IEC 60068-2-29) |
| Weight: | 2,530 g |
| Supply voltage typical, from, to: | 24 V DC, 19.2 V DC, 28.8 V DC |
| Wave length: | 950 nm |
| Connection type: | Hirschmann plug M26 x 11 + FE, straight |
| Connection type configuration connection: | M8 x 4 |
| Maximum connection cable cross-section: | 0.75 mm2 |
| Technical Data-Receiver | |
| Protective field height: | 1,200 mm |
| Resolution: | 30 mm |
| Scanning range from … to: | 0 m … 19 m |
| Scanning range from … to (delivery status): | 0 m … 6 m |
| Housing length: | 1,329 mm |
| Housing cross-section: | 48 mm x 40 mm |
| Type: | Type 4 (IEC 61496) |
| Safety integrity level: | SIL3 (IEC 61508), SILCL3 (IEC 62061) |
| Category: | category 4 (EN ISO 13849) |
| Performance level: | PL e (EN ISO 13849) |
| PFHd: | 1.5 * 1E-08 |
| TM (Mission Time): | 20 a |
| Enclosure rating: | IP 65 |
| Protection class: | III |
| Ambient operating temperature from … to: | 0 °C … 55 °C |
| Vibration resistance (checked to): | 5 g (IEC 60068-2-6) |
| Oscillation frequency from … to: | 10 Hz … 55 Hz |
| Shock resistance: | 10 g, 16 ms (IEC 60068-2-29) |
| Weight: | 2,560 g |
| Response time without beam coding: | ≤ 13 ms |
| Response time with beam coding: | ≤ 21 ms |
| Supply voltage typical, from, to: | 24 V DC, 19.2 V DC, 28.8 V DC |
| Maximum switching current: | 500 mA |
| Wave length: | 950 nm |
| Connection type: | Hirschmann plug M26 x 11 + FE, straight |
| Connection type configuration connection: | M8 x 4 |
| Maximum connection cable cross-section: | 0.75 mm2 |






Reviews