FESTO CMMP-AS-C10-11A-P3-M0

Description

FESTO CMMP-AS-C10-11A-P3-M0

FESTO CMMP-AS-C10-11A-P3-M3

FESTO CMMP-AS-C5-11A-P3-M3

Nominal current
11 A
Nominal operating voltage AC
400 V
Phases of nominal operating voltage
3-phase
Controller nominal output
6000 VA
Fieldbus link
CANopen – DeviceNet – EtherCAT – EtherNet/IP –

Festo CMMP-AS-C10-11A-P3-M0 (1622904) Motor Controller

Motor controller

CMMP-AS-C10-11A-P3-M3 1501328

Technical Data

  • Type of mountingOn sub-base Screw-clamped
  • Product weight3450 g
  • Display7-segment display
  • ApprovalRCM trademark c UL us listed (OL)
  • CE mark (see declaration of conformity)To EU EMC Directive To EC Machinery Directive To EU Low Voltage Directive In accordance with EU RoHS Directive
  • UKCA marking (see declaration of conformity)To UK instructions for EMC To UK regulations for machines To UK RoHS instructions To UK regulations for electrical equipment
  • Storage temperature-25 °C … 70 °C
  • Ambient temperature0 °C … 40 °C
  • Relative air humidity0 – 90%
  • Degree of protectionIP10 IP20
  • Pollution degree2
  • Note on materialsRoHS-compliant
  • LABS (PWIS) conformityVDMA24364 zone III
  • Phases of nominal operating voltage3-phase
  • Nominal operating voltage AC400 V
  • Permissible voltage fluctuations+/- 10 %
  • Mains frequency50 Hz … 60 Hz
  • Nominal current11 A
  • Mains filterIntegrated
  • Max. intermediate circuit voltage DC560 V
  • Brake resistance68 Ohm
  • Pulse power, brake resistance8.5 kVA
  • Nominal voltage for logic power supply DC24 V
  • Permissible range for logic voltage± 20 %
  • Current consumption of logic power supply without clamping brake1 A
  • Output voltage class AC3x 0 – 360 V
  • Nominal output current10 A
  • Nominal current per phase, effective10 A
  • Peak current per phase, effective20 A
  • Max. peak current duration5 s
  • Controller nominal output6000 VA
  • Maximum output12000 VA
  • Output frequency0 Hz … 1000 Hz
  • Parameterisation interfaceParameterisation and commissioning USB Ethernet
  • Fieldbus linkCANopen DeviceNet EtherCAT EtherNet/IP Modbus/TCP PROFINET Profibus DP
  • Communication profileDS301/DSP402 FHPP
  • Process interfacingI/O coupling For 256 position sets
  • Max. fieldbus transmission rate1 Mbit/s
  • Bus connectionPlugs 9-pin Sub-D
  • Encoder interface output, featuresResolution 16384 ppr
  • Encoder interface output, functionActual value feedback via encoder signals in speed control mode. Setpoint specification for downstream slave drive.
  • Encoder interface input, features3-phase encoder signals EnDat HIPERFACE RS422 SINCOS
  • Encoder interface input, functionSetpoint speed value as encoder signal Specifies the speed of the slave drive in synchronous mode.
  • Number of digital logic inputs10
  • Features of logic inputGalvanically isolated Freely configurable
  • Working range of logic input8 V … 30 V
  • Number of digital logic outputs 24 V DC5
  • Features of digital logic outputsGalvanically isolated Freely configurable in some cases
  • Max. current digital logic outputs100 mA
  • Number of analogue setpoint inputs2
  • Features of setpoint inputsDifferential inputs Configurable for speed Configurable for current
  • Working range setpoint input± 10 V
  • Impedance of setpoint input20 kOhm
  • Number of analogue monitor outputs2
  • Working range of monitor outputs± 10 V
  • Resolution of monitor outputs9 bit
  • Features of monitor outputsShort-circuit proof