Chế độ PID mới giúp điều chỉnh nhiệt độ chính xác Chu kỳ cao 0.25s Thiết kế nhỏ ngọn Dễ dàng cài đặt vận hành Tín hiệu đầu vào đa dạng Hỗ trợ RS485. – Nguồn cấp bộ điều khiển nhiệt độ: 110~240 VAC, 24VDC Option. – Công suất tiêu thụ: 10VA. – Ngõ vào input

STANDARD SPECIFICATIONS
Input Type |
Thermocouple |
K, J, T, R, N, S, B (Input Resistance: 1M Ω ) |
Thermocouple / R.T.D. Input, Current / Voltage Input are switchable with the front key. |
||
R.T.D. |
Pt100, JPt100 (provided that the external resistance is below 10 Ω (per wire) and 3 wires have all the same resistance) |
||||
Current / Voltage |
4 – 20mADC (Input Resistance 250 Ω ), 0 – 5 VDC / 1 – 5 VDC (Input Resistance above 500k Ω ) (Measured Current Appx. 2mA) |
||||
Indication |
PV Character |
4-digits White 10mm height (7.6mm height for TTM-002W, 14mm height for TTM-006W / 009W) |
|||
SV Set Value |
4-digist Green 8mm height (5.25mm height for TTM-002W) |
||||
Various Function |
LED: Red (AL1, AL2, OUT1, OUT2, RDY), LED: Green (COM, DI), COM for TTM-002W is at 1st decimal digit of display. |
||||
Control Method |
PID Auto-Tuning Self-Tuning |
Proportional band (P1) |
0.1 to 200.0% of the setting limiter span |
||
Proportional band (P2) at Output 2 side. |
0.10 to 10.00 times (magnification over the proportional band P1) |
||||
Integral Time (I) |
0 to 3600 sec. (Integral Control Action becomes OFF at 0). |
||||
Derivative Time (D) |
0 to 3600 sec. (Derivative Action becomes OFF at 0). |
||||
Proportional Cycle (T1, T2) |
1 to 120 sec. |
||||
Dead Band (DB) |
Temp. Input |
-100.0 to +100.0 or -100 to +100(℃ ) |
|||
Analogue Input |
-1000 to 1000 (digit) (Decimal point is at designated place) |
||||
ON / OFF |
Control Sensitivity (C1, C2) |
Temp. Input |
0 to 999 or 0.0 to 999.9(℃ ) |
||
Analogue Input |
0 to 9999 (digit) (Decimal point is at designated place) |
||||
OFF point of Output 1 & 2 |
Position Setting |
Temp. Input |
-199 to 999 or -199.9 to 999.9(℃ ) |
||
Analogue Input |
-1999 to 9999 (digit) (Decimal point is at designated place) |
||||
Control Output |
Relay Contact |
250VAC, 3A (Resistance Load) 1a contact (On heating / cooling operation, output 2 is 250VAC, 2.4A (Load Resistance) 1a contact) |
|||
SSR Drive Voltage |
0 to 12VDC (Load Resistance: 600 Ω or more) |
||||
Current |
4 to 20mADC (Load Resistance: Below 600 Ω ) |
||||
Sampling Time |
0.25 sec. (Output change cycle is also the same) |
||||
Setting and Indication Accuracy |
Thermocouple |
± (0.3% + 1-digit) of input value or ± 2℃ , whichever is bigger (Ambient Temp.: 23℃± 10℃ ) However -99 to 0℃ : ± 3℃ -210 to -100℃ : ± 4℃ Thermocouple B under 400℃ is not regulated. |
|||
R.T.D. |
± (0.3% + 1-digit) of input value or ± 0.9℃ , whichever is bigger (Ambient Temp.: 23℃± 10℃ ) |
||||
Current (4-20mA), Voltage (0 – 5VDC, 1 – 5VDC) |
± (0.3% + 1-digit) of setting value limiter span (Ambient Temp.: 23℃± 10℃ ) |
||||
Memory Element |
EEPROM |
||||
Input Voltage |
100 – 240VAC (-15%, +10%) or 24V AC/DC ( ± 10%) 50/60Hz * For transfer output models, 24V AC/DC is not selectable. |
||||
Weight |
TTM-002W / 004W: below 180gms., TTM-005W / 006W: below 300gms., TTM-007W: below 250gms., TTM-009W: below 380gms. |
||||
Power Consumption |
10VA (264VAC), 6VA (24VAC), 4W (24VDC) |
||||
Accessories |
Instruction Manual & mounting attachment (TTM-002W, 004W), metal mounting bracket (TTM-005W, 006W, 007W, 009W) |
||||
Suitable Operating Environment |
0 to 50℃ , 20 to 90% RH (no condensation) |
||||
Suitable Storage Environment |
-25℃ to 70℃ , 5 to 95% RH (no icing and condensation) |
||||
Functions |
Manipulated Variable Limiter (ML1, MH1, ML2, MH2) |
0.0 (-10.0) to 100.0 (110.0)% Values indicated in ( ) are for current / voltage models. |
|||
Set Limiter (SLL, SLH) |
See “Input & Scale Range Table”. |
||||
Selectable Control Mode(CNT) |
Auto-Tuning PID Type A (Normal / Reverse Action), Auto-Tuning PID Type B (Normal / Reverse Action), Self-Tuning PID (Normal / Reverse Action), ON / OFF (Normal / Reverse Action) |
||||
PV Correction 0-point Setting (PVS) |
Thermocouple / R.T.D.: -199 to 999 or -199.9 to 999.9 (℃ ) Current / Voltage (Decimal point at designated position): -1999 to 9999 (digit) |
||||
PV Correction Gain Setting |
0.50 to 2.00 (times) |
||||
Input Filter |
0.0 to 99.9 (sec.) |
||||
Manual Reset (PBB) |
0.0 to 100.0%, -100.0 to +100.0 (heating / cooling) of proportional band. |
||||
Timer Operation Mode (TMM) |
0 min. 00 sec. to 59 min. 59 sec. 0 hr. 00 min. to 99 hrs. 59 min. Accuracy: ± (1.5%+0.5 sec.) of the set time. |
||||
Decimal Point Shift (DP) |
Indication after the decimal point Yes / No |
||||
Manual Control |
Manual control is possible (Balanceless / Bumpless) |
||||
RUN / READY |
RUN / READY is switchable |
||||
Blind Function |
A non-indication is possible for any unnecessary parameter screen. |
||||
Auto-Tuning (AT) Coefficient |
A coefficient can be set to the proportional band which is computed by the Auto-Tuning. |
||||
FUNC Key |
Selectable from “Digit Shift”, “AT”, “RUN / READY”, “Timer Start / Reset”. |
||||
Priority Display |
Selected parameter screen can be displayed in the operation mode (9-points) |
||||
Lock Function (LOC) |
4-modes (OFF, ALL, Operation Mode Lock, Lock except Operation Mode) |
||||
Self-Checking Function |
EEPROM Data Check (Err0), A/D Converter Operation Check (Err1), Auto-Tuning Check (Err2), Built-In Watchdog Timer |
||||
Ramp Function |
Operation: When the SV is changed, it sets the SV changes per minute. The setting can be done individually for SV & SV2 respectively. *SV2 is available when option DI is selected. Setting Range: 0.0 to 999.9 The ramp function is disabled by 0.0 setting. Setting Unit: 0.1℃ /min. (thermocouple / R.T.D. input model) 0.1-digit/min. of SV setting unit (analogue input model) |
||||
External Standard |
6 substances as restricted by the RoHS Directives are not used. |
Lead: Below 1,000 ppm Mercury: Below 1,000 ppm Cadmium: Below 100 ppm Hexad Chrome: Below 1,000 ppm Polybrominated Biphenyl (PBB): Below 1,000 ppm Polybrominated Diphenyl Ethers (PBDE): Below 1,000 ppm |
|||
UL/cUL/CE Markings (except TTM-002W) |
ADDITIONAL FUNCTIONS (Option)
Event Output 1 (AL 1) Event Output 2 (AL2 or OUT2) |
Function: PV event contact output (8 modes), Special functions (3 modes), additonal functions (3 modes) Setting Range: Thermocouple / R.T.D: -199.9 to 999.9 or -1999 to 3276 (℃ ) Current / Voltage (decimal point at designated position): 0 to 9999 (digit) Sensitivity: Thermocouple / R.T.D: 0.0 to 999.9 or 0 to 999 (℃ ) Current / Voltage (decimal point at designated position): 0 to 9999 (digit) Rating: 250VAC 2.4A (resistance load) 1a contact When OUT2 is selected at contact output 2, the cooling side output of the heating / cooling control will be generated. Contact polarity is selectable (normal open / normal close). When OUT2 is SSR, the output voltage shall be 0 to 12VDC (load resistance: above 600 Ω ) |
DI |
Function: SV / SV2 switchable (OFF: SV2), Auto / Manual switchable (OFF: Manual), RUN / READY switchable (OFF: READY), Normal / Reverse action switchable (OFF: Normal), Normal action (SV2) / Reverse action (SV2) switchable (OFF: Normal SV2), Timer Start / Reset (OFF: counting) Input Specifications: Min. input time: 500mS, OFF voltage: 6VDC max., ON current: 6mA max., permissible resistance value between terminals: ON = 333 Ω max., OFF = 500k Ω min. |
CT Input |
Setting Range: 1 to 30A AC, Accuracy: ±5% (setting resolution 1A)of FS, Detection of wire malfunction: when the ON time of OUT1 is above 300mS. Welding detection: when the OFF time of OUT1 is above 300mS. |
Heating & Cooling |
Refer to “Use of Control Output” |
Communication |
Multi-drop system (1:31 stations) Direction of Information: Semi-duplex Synchronous method: Asynchronous Transfer code: TOHO protocol ASCII (BCC is excluded) MODBUS RTU / ASCII Interface: Two-wire system Communication speed: 1200 / 2400 / 4800 / 9600 / 19200 BPS Character: Start bit 1 bit fixed Stop bit 1/2 bit Data length – TOHO Protocol 7/8 bit
Parity None / odd no. / even no. BCC check – TOHO Protocol No / Yes (The error check will be done by CRC for MODBUS RTU, LRC for MODBUS ASCII) Address – TOHO Protocol 1 to 99
Response delay time: 0 to 250mS
|
Transfer Output |
FUNCTION: PV (Measured Value) Output, SV (Set Value) Output, MV (OUT1 Manipulated Variable) Output Output Accuracy FS ± 0.3% (ambient temp. 23 ± 10℃ ) 0 to 10mV DC, 0 to 1V, 0 to 5V, 1 to 5V, 0 to 10V, 4 to 20mA Normal / Reverse switchable |
INPUT and SCALE RANGE
(Thermocouples & R.T.D. are switchable freely)
Thermocouple |
Set Range |
Display Range |
|||
No decimal point |
w/ decimal point |
No decimal point |
w/ decimal point |
||
K |
℃ |
-200 to 1372 |
-199.9 to 990.0 |
-210 to 1382 |
-199.9 to 999.9 |
J |
℃ |
-200 to 850 |
-199.9 to 850.0 |
-210 to 860 |
-199.9 to 860.0 |
R |
℃ |
0 to 1700 |
――――― |
-10 to 1710 |
――――― |
T |
℃ |
-200 to 400 |
-199.9 to 400.0 |
-210 to 410 |
-199.9 to 410.0 |
N |
℃ |
-200 to 1300 |
-199.9 to 990.0 |
-210 to 1310 |
-199.9 to 999.9 |
S |
℃ |
0 to 1700 |
――――― |
-10 to 1710 |
――――― |
B |
℃ |
0 to 1800 |
――――― |
-20 to 1820 |
――――― |
R.T.D. |
Set Range |
Display Range |
|||
No decimal point |
w/ decimal point |
No decimal point |
w/ decimal point |
||
Pt100 (JIS/IEC) |
℃ |
-199 to 500 |
-199.9 to 500.0 |
-199 to 530 |
-199.9 to 520.0 |
JPt100 (JIS) |
℃ |
-199 to 500 |
-199.9 to 500.0 |
-199 to 510 |
-199.9 to 520.0 |
Các sản phẩm liên quan
TTM-006W-I-A
TTM-006W-P-A
TTM-009W-R-A
TTM-004W-R-A
TTM-009W-I-A
TTM-009W-P-A
TTM-004W-P-A
TTM-004W-I-A
Đại lý TOHO vietnam, TOHO viet nam, TOHO vietnam distributor, Phân phối TOHO tại việt nam
Đại lý TOHO vietnam, TOHO viet nam, TOHO vietnam distributor, Phân phối TOHO tại việt nam
Đại lý TOHO vietnam, TOHO viet nam, TOHO vietnam distributor, Phân phối TOHO tại việt nam
Đại lý TOHO vietnam, TOHO viet nam, TOHO vietnam distributor, Phân phối TOHO tại việt nam
Đại lý TOHO vietnam, TOHO viet nam, TOHO vietnam distributor, Phân phối TOHO tại việt nam
Reviews
There are no reviews yet.