TOHO TTM-006W-R-A

Description

TOHO TTM-006W-R-A

Chế độ PID mới giúp điều chỉnh nhiệt độ chính xác Chu kỳ cao 0.25s Thiết kế nhỏ ngọn Dễ dàng cài đặt vận hành Tín hiệu đầu vào đa dạng Hỗ trợ RS485. – Nguồn cấp bộ điều khiển nhiệt độ: 110~240 VAC, 24VDC Option. – Công suất tiêu thụ: 10VA. – Ngõ vào input

● Self-Tuning PID (Heating / Cooling)
The most appropriate PID constant is automatically computed for the controlled objects.
PID constant is computed by performing the tuning, or when the hunting occurs.
● Blind Function
From the various existing parameters, only the required parameters can be
indicated or set.
● Simplififi ed Timer Function
ON/OFF setting control is available after some certain interval. Function of ON/
OFF alarm output is independently usable.
● Priority Display
Demanding parameter screens are monitored and set up under operational mode
screen. (max. 9 points)
● Multiple Inputs
Thermocouple / R.T.D. (Pt100 & JPt100) are selectable by front key.
● External Standard
Conforms to “UL”, “cUL” and “CE” markings (except TTM-002W) and compliant to
“IP66″equivalent.
The 6 substances restricted by the RoHS directives are not used.
● Compact Size
Compactly made with the depth of only 77mm (002W is 95mm).
● Manual Control (Balanceless & Bumpless)
Manual output function is applicable for versatile applications of instrumentation
systems.
● Sampling Cycle: 250mS
● Communication Function (RS-485: TOHO Protocol / MODBUS)
The communication distance is extended up to 500 m, and max. of 31 units
of controllers can be connected to a single computer at a time. Centralized
supervision is available for collectiion of the whole data and alterration of setting
values at remote location.
● Digital PV Filter
A fi ltering is possible with a software for abrupt alteration of input value.
● PID with Overshoot Control Function
A PID control is available to control the overshoot which occurs when the control
is just starting.
Further, in order to improve the controllability, PID algorithm of TTM-200 series
had been introduced.
● DI Function
The following functions are switchable:
① SV / SV2
② RUN / READY
③ AUTO (RUN) / Manual
④ Normal / Reverse Action
⑤ AT (Auto-Tuning) Start
⑥ Normal (SV2) / Reverse Action (SV)
⑦ TIMER Start / Reset
● Others
① CT Input (w/ Input Monitor)
② Shift setting of OFF position during the ON / OFF control (for both Output 1 & 2).
③ Heating / Cooling Control (w/ PID Control Function on Cooling Side).
④ Ramp Function
Hướng dẫn chọn mã hàng TTM

STANDARD SPECIFICATIONS

Input Type

Thermocouple

K, J, T, R, N, S, B (Input Resistance: 1M Ω )

Thermocouple /

R.T.D. Input, Current / Voltage Input are switchable with the front key.

R.T.D.

Pt100, JPt100 (provided that the external resistance is below 10 Ω (per wire) and 3 wires have all the same resistance)

Current / Voltage

4 – 20mADC (Input Resistance 250 Ω ), 0 – 5 VDC / 1 – 5 VDC (Input Resistance above 500k Ω ) (Measured Current Appx. 2mA)

Indication

PV Character

4-digits White 10mm height (7.6mm height for TTM-002W, 14mm height for TTM-006W / 009W)

SV Set Value

4-digist Green 8mm height (5.25mm height for TTM-002W)

Various Function

LED: Red (AL1, AL2, OUT1, OUT2, RDY), LED: Green (COM, DI), COM for TTM-002W is at 1st decimal digit of display.

Control Method

PID

Auto-Tuning Self-Tuning

Proportional band (P1)

0.1 to 200.0% of the setting limiter span

Proportional band (P2) at Output 2 side.

0.10 to 10.00 times (magnification over the proportional band P1)

Integral Time (I)

0 to 3600 sec. (Integral Control Action becomes OFF at 0).

Derivative Time (D)

0 to 3600 sec. (Derivative Action becomes OFF at 0).

Proportional Cycle (T1, T2)

1 to 120 sec.

Dead Band (DB)

Temp. Input

-100.0 to +100.0 or -100 to +100(℃ )

Analogue Input

-1000 to 1000 (digit) (Decimal point is at designated place)

ON / OFF

Control Sensitivity (C1, C2)

Temp. Input

0 to 999 or 0.0 to 999.9(℃ )

Analogue Input

0 to 9999 (digit) (Decimal point is at designated place)

OFF point of Output 1 & 2

Position Setting

Temp. Input

-199 to 999 or -199.9 to 999.9(℃ )

Analogue Input

-1999 to 9999 (digit) (Decimal point is at designated place)

Control Output

Relay Contact

250VAC, 3A (Resistance Load) 1a contact (On heating / cooling operation, output 2 is 250VAC, 2.4A (Load Resistance) 1a contact)

SSR Drive Voltage

0 to 12VDC (Load Resistance: 600 Ω or more)

Current

4 to 20mADC (Load Resistance: Below 600 Ω )

Sampling Time

0.25 sec. (Output change cycle is also the same)

Setting and Indication Accuracy

Thermocouple

± (0.3% + 1-digit) of input value or ± 2℃ , whichever is bigger (Ambient Temp.: 23℃± 10℃ ) However -99 to 0℃ : ± 3℃ -210 to -100℃ : ± 4℃ Thermocouple B under 400℃ is not regulated.

R.T.D.

± (0.3% + 1-digit) of input value or ± 0.9℃ , whichever is bigger (Ambient Temp.: 23℃± 10℃ )

Current    (4-20mA), Voltage (0 – 5VDC, 1 – 5VDC)

± (0.3% + 1-digit) of setting value limiter span (Ambient Temp.: 23℃± 10℃ )

Memory Element

EEPROM

Input Voltage

100 – 240VAC (-15%, +10%) or 24V AC/DC ( ± 10%) 50/60Hz * For transfer output models, 24V AC/DC is not selectable.

Weight

TTM-002W / 004W: below 180gms., TTM-005W / 006W: below 300gms., TTM-007W: below 250gms., TTM-009W: below 380gms.

Power Consumption

10VA (264VAC), 6VA (24VAC), 4W (24VDC)

Accessories

Instruction Manual & mounting attachment (TTM-002W, 004W), metal mounting bracket (TTM-005W, 006W, 007W, 009W)

Suitable Operating Environment

0 to 50℃ , 20 to 90% RH (no condensation)

Suitable Storage Environment

-25℃ to 70℃ , 5 to 95% RH (no icing and condensation)

Functions

Manipulated Variable Limiter       (ML1, MH1, ML2, MH2)

0.0 (-10.0) to 100.0 (110.0)% Values indicated in ( ) are for current / voltage models.

Set Limiter (SLL, SLH)

See “Input & Scale Range Table”.

Selectable Control Mode(CNT)

Auto-Tuning PID Type A (Normal / Reverse Action), Auto-Tuning PID Type B (Normal / Reverse Action), Self-Tuning PID (Normal / Reverse Action), ON / OFF (Normal / Reverse Action)

PV Correction 0-point Setting (PVS)

Thermocouple / R.T.D.: -199 to 999 or -199.9 to 999.9 (℃ ) Current / Voltage (Decimal point at designated position): -1999 to 9999 (digit)

PV Correction Gain Setting

0.50 to 2.00 (times)

Input Filter

0.0 to 99.9 (sec.)

Manual Reset (PBB)

0.0 to 100.0%, -100.0 to +100.0 (heating / cooling) of proportional band.

Timer Operation Mode (TMM)

0 min. 00 sec. to 59 min. 59 sec. 0 hr. 00 min. to 99 hrs. 59 min. Accuracy: ± (1.5%+0.5 sec.) of the set time.

Decimal Point Shift (DP)

Indication after the decimal point Yes / No

Manual Control

Manual control is possible (Balanceless / Bumpless)

RUN / READY

RUN / READY is switchable

Blind Function

A non-indication is possible for any unnecessary parameter screen.

Auto-Tuning (AT) Coefficient

A coefficient can be set to the proportional band which is computed by the Auto-Tuning.

FUNC Key

Selectable from “Digit Shift”, “AT”, “RUN / READY”, “Timer Start / Reset”.

Priority Display

Selected parameter screen can be displayed in the operation mode (9-points)

Lock Function (LOC)

4-modes (OFF, ALL, Operation Mode Lock, Lock except Operation Mode)

Self-Checking Function

EEPROM Data Check (Err0), A/D Converter Operation Check (Err1), Auto-Tuning Check (Err2), Built-In Watchdog Timer

Ramp Function

Operation: When the SV is changed, it sets the SV changes per minute.

The setting can be done individually for SV & SV2 respectively.

*SV2 is available when option DI is selected.

Setting Range: 0.0 to 999.9

The ramp function is disabled by 0.0 setting.

Setting Unit:   0.1℃ /min. (thermocouple / R.T.D. input model)

0.1-digit/min. of SV setting unit (analogue input model)

External Standard

6 substances as restricted by the RoHS Directives are not used.

Lead:     Below      1,000      ppm Mercury: Below 1,000 ppm         Cadmium:      Below      100      ppm Hexad Chrome: Below 1,000 ppm Polybrominated Biphenyl (PBB): Below 1,000 ppm

Polybrominated Diphenyl Ethers (PBDE): Below 1,000 ppm

UL/cUL/CE Markings (except TTM-002W)

ADDITIONAL FUNCTIONS (Option)

Event Output 1 (AL 1) Event Output 2 (AL2 or OUT2)

Function: PV event contact output (8 modes), Special functions (3 modes), additonal functions (3 modes) Setting Range: Thermocouple / R.T.D: -199.9 to 999.9 or -1999 to 3276 (℃ )

Current / Voltage (decimal point at designated position): 0 to 9999 (digit) Sensitivity: Thermocouple / R.T.D: 0.0 to 999.9 or 0 to 999 (℃ )

Current / Voltage (decimal point at designated position): 0 to 9999 (digit)

Rating: 250VAC 2.4A (resistance load) 1a contact When OUT2 is selected at contact output 2, the cooling side output of the heating / cooling control will be generated.

Contact   polarity   is    selectable    (normal    open    /    normal    close). When OUT2 is SSR, the output voltage shall be 0 to 12VDC (load resistance: above 600 Ω )

DI

Function:      SV / SV2 switchable (OFF: SV2), Auto / Manual switchable (OFF: Manual), RUN / READY switchable (OFF: READY), Normal / Reverse action switchable (OFF: Normal), Normal action (SV2) / Reverse action (SV2) switchable (OFF: Normal SV2), Timer Start / Reset (OFF: counting)

Input Specifications: Min. input time: 500mS, OFF voltage: 6VDC max., ON current: 6mA max., permissible resistance value between terminals: ON = 333 Ω max., OFF = 500k Ω min.

CT Input

Setting Range:  1 to 30A AC, Accuracy: ±5% (setting resolution 1A)of FS, Detection of wire malfunction: when the ON time of OUT1 is above 300mS.

Welding detection: when the OFF time of OUT1 is above 300mS.

Heating & Cooling

Refer to “Use of Control Output”

Communication

  1. Communication Standard : RS-485 conformable

  2. Communication Method   : Protocol: TOHO protocol / MODBUS

Multi-drop    system    (1:31     stations) Direction of Information: Semi-duplex Synchronous      method:      Asynchronous Transfer code: TOHO protocol ASCII (BCC is excluded)

MODBUS RTU / ASCII

Interface:           Two-wire           system Communication speed: 1200 / 2400 / 4800 / 9600 / 19200 BPS Character: Start bit 1 bit fixed

Stop bit 1/2 bit

Data length – TOHO Protocol 7/8 bit

  • MODBUS RTU 8 bit

  • MODBUS ASCII 7 bit

Parity None / odd no. / even no.

BCC check – TOHO Protocol No / Yes

(The error check will be done by CRC for MODBUS RTU, LRC for MODBUS ASCII) Address – TOHO Protocol 1 to 99

  • MODBUS RTU and ASCII 1 to 247

Response delay time: 0 to 250mS

  1. Isolation: Isolated from power circuit and CPU circuit.

Transfer Output

FUNCTION: PV (Measured Value) Output, SV (Set Value) Output, MV (OUT1 Manipulated Variable) Output Output   Accuracy   FS   ±   0.3%   (ambient   temp.   23   ±   10℃   ) 0 to 10mV DC, 0 to 1V, 0 to 5V, 1 to 5V, 0 to 10V, 4 to 20mA Normal / Reverse switchable

INPUT and SCALE RANGE

(Thermocouples & R.T.D. are switchable freely)

Thermocouple

Set Range

Display Range

No decimal point

w/ decimal point

No decimal point

w/ decimal point

K

-200 to 1372

-199.9 to 990.0

-210 to 1382

-199.9 to 999.9

J

-200 to 850

-199.9 to 850.0

-210 to 860

-199.9 to 860.0

R

0 to 1700

―――――

-10 to 1710

―――――

T

-200 to 400

-199.9 to 400.0

-210 to 410

-199.9 to 410.0

N

-200 to 1300

-199.9 to 990.0

-210 to 1310

-199.9 to 999.9

S

0 to 1700

―――――

-10 to 1710

―――――

B

0 to 1800

―――――

-20 to 1820

―――――

R.T.D.

Set Range

Display Range

No decimal point

w/ decimal point

No decimal point

w/ decimal point

Pt100 (JIS/IEC)

-199 to 500

-199.9 to 500.0

-199 to 530

-199.9 to 520.0

JPt100 (JIS)

-199 to 500

-199.9 to 500.0

-199 to 510

-199.9 to 520.0

Các sản phẩm liên quan

TTM-006W-I-A

TTM-006W-P-A

TTM-009W-R-A

TTM-004W-R-A

TTM-009W-I-A

TTM-009W-P-A

TTM-004W-P-A

TTM-004W-I-A

 

Đại lý TOHO vietnam, TOHO viet nam, TOHO vietnam distributor, Phân phối TOHO tại việt nam

Đại lý TOHO vietnam, TOHO viet nam, TOHO vietnam distributor, Phân phối TOHO tại việt nam

Đại lý TOHO vietnam, TOHO viet nam, TOHO vietnam distributor, Phân phối TOHO tại việt nam

Đại lý TOHO vietnam, TOHO viet nam, TOHO vietnam distributor, Phân phối TOHO tại việt nam

Đại lý TOHO vietnam, TOHO viet nam, TOHO vietnam distributor, Phân phối TOHO tại việt nam

Reviews

There are no reviews yet.

Be the first to review “TOHO TTM-006W-R-A”

Email của bạn sẽ không được hiển thị công khai. Các trường bắt buộc được đánh dấu *